When the ratio of the washing machine operating frequency to the platform natural
frequency (f/fo) is less than √2, the vibration is amplified, and when this ratio
is greater than 11/2, any vibrations are isolated.
As the system proceeds through f/fo of 1 is when the vibrations are the most greatly
amplified.
The steadywash™ possesses non-linear behavior through resonance, which significantly
reduces the level of vibration, even at f/fo = 1